Manufactured from an extra High Impact grade of uPVC, LITAFLEX AIR–CONDITIONING TRUNKING is Fire Resistant rated and complies with the Singapore Standard SS 275: 1999.
To facilitate distribution from the outdoor Air-Conditioning Condensing Unit to the Fan Coil Unit mounted on the wall of the living room, LITAFLEX has intelligently design this non-corrosive Trunking system to secure Electrical Cables, Insulation Tubes containing Copper Tubes and uPVC Drain Pipes.
LITAFLEX's latest NEW design on the Base and 'snap-on' lids provide a stronger grip, easy installation and also the removal for maintenance. The unique characteristics of its clean and smooth curvy edges, strength and durability allow it to be used even on rough wall surfaces and ceilings.
What is more, LITAFLEX's air-conditioning trunking is made of high weather resistant, which ensures a lasting appearance of beauty.
|
| uPVC AIR - CONDITIONING TRUNKING | |
TK 040025 TK 040040 |
40mm X 25mm 40mm X 40mm |
10 10 |
20 20 |
TK 050032 TK 050040 TK 050050 |
50mm X 32mm 50mm X 40mm 50mm X 50mm |
10 10 10 |
20 20 20 |
TK 075050 TK 075060 TK 075075 |
75mm X 50mm 75mm X 60mm 75mm X 75mm |
5 5 4 |
10 10 10 |
TK 085065 TK 105065 |
85mm X 65mm 105mm X 65mm |
4 4 |
8 8 |
TK 100050 TK 100060 TK 100080 TK 100100 |
100mm X 50mm 100mm X 60mm 100mm X 80mm 100mm X 100mm |
5 5 4 2 |
10 10 8 6 |
TK 125055 TK 125100 |
125mm X 55mm 125mm X 100mm |
5 2 |
10 6 |
TK 150080 TK 150100 |
150mm X 80mm 150mm X 100mm |
2 2 |
6 6 |
TK 200055 TK 200100 |
200mm X 55mm 200mm X 100mm |
2 2 |
2 2 |
|
STANDARD LENGTH |
: |
2.44M |
|
COLOUR |
: |
WHITE |
|
|
Smooth finishing to match interior and exterior of buildings
|
|
|
Installation Capacity of Multi Split Unit Air-Conditioning System
|
1 Condensing Unit to 1 Fan Coil
|
Insulated Drain Pipe
|
1 Condensing Unit to 2 Fan Coil
|
|
I Condensing Unit to I Fan Coil
Mechanical Properties Cable Supporting Test for surface mounting Temperature Duration Distortion (Max) |
60 ± 2°C 2 hr 10% |
|
|
Impact Test Precondition Duration Test Temperature Mass of Hammer Height of Impact |
|
60 ± 2°C 240hr 15°C 2 kg 100 mm |
|
|
Cover Retention Test Mass attached to Cover Duration of Test |
2 kg 60 sec |
 |
Resistant to Heat Testing Temperature Applied force of Ball Pressure Duration of Test Diameter of impression |
60 ± 2°C 20 N 1 hr < 2 mm |
|
|
Resistance to Flame Propagation Flame Test |
Does not ignite or flames. Self extinguished within 30s after removal of flame. |
|
|
Insulating Characteristics Electric Insulating Strength Test Applied Voltage Duration of Electrication |
2500 V 1 min |
|
|
Insulation Resistance test Applied Voltage Duration of Electrification |
500 V dc 1 min |
|
|